Вычислительный модуль

Used to acquire product level, temperature, interface, pressure differential value from each tank gauging devices, and convert pressure differential value density into density, and send all of these data to tank gauging management system.
Share:
Вычислительный модуль

Function:

Used to acquire product level, temperature, interface, pressure differential value from each tank gauging devices, and convert pressure differential value density into density, and send all of these data to tank gauging management system.



∗ With functions of density calculation by data from differential pressure transmitter;

∗ Build in lightening protection module, to ensure reliable working;

∗ Support various communication protocols;

∗ On-site display for all the data.

Measuring accuracy
< 0.2 %
Voltage
24V/DC
Current
40mA
Ambient Temp.
-35℃ ~ +70
Electrical interface
2 of 1/2 NPT 4 of 3/4 NPT
Signal input
HART two-way
4-20mA one-way
RS 485 one-way
Enraf BPM protocol two-way
Out put signal
RS 485
Explosion proof rating
Exd II BT4 Gb
Protection level
IP 65
Net weight
5.1 kg
Dimension
256mm*178mm*105mm
Your name :
        
Title :
Contact Number :
E-mail :
Contact Address :
leave Comments :
    
.